x32: Check for Shorts to Ground in the HEDF Circuit
Steps _Key Off
_Breakout box installed
_Processor and Integrated Controller disconnected
_DVOM on 200,000 ohm scale
_Measure resistance between Test Pin 52 and Test Pin 40
Result Is resistance less than 10,000 ohms?
Direction NO

GO to Continue

YES

Remove breakout box. Reconnect processor and Integrated Controller. Service short to ground in HEDF circuit. Rerun Quick Test.