Turbo Coupe Technical Articles Turbo Coupe Literature Contact
h5: Isolate Faulty Injector Circuit
Steps _Key Off
_Breakout box installed
_Disconnect all injectors on suspect bank
_Processor disconnected
_DVOM on 200 ohm scale
_Connect one injector and measure resistance between Test Pin 37 and either Test Pin 58 or 59 as appropriate.
_Disconnect that injector and repeat process for each of the remaining injectors.
_Refer to Injector Resistance Specification Table #2
Result Is/are resistance(s) within specifications for the the appropriate engine?
Direction YES

GO to Continue

NO

Remove breakout box. Reconnect processor and injectors. Service open/short circuit in injector harness. If OK, replace injector. Rerun Quick Test