Turbo Coupe Technical Articles Turbo Coupe Literature Contact
c4: Check for Excess Voltage on VREF Circuit
Steps _Key Off, wait 10 seconds
_Breakout box installed
_Disconnect processor
_Key On, engine Off
_DVOM on 20 volt scale
_Measure voltage between Test Pin 26 at the breakout box and battery ground
Result Is voltage less than .5 volts?
Direction YES

Remove breakout box. Reconnect sensor. Replace processor. Rerun Quick Test

NO

Service short to battery power in EEC harness. Remove breakout box. Reconnect processor and sensor. Rerun Quick Test. If condition persists, replace processor.